CU THWN-2 is a 600V copper building wire designed for general-purpose electrical wiring in residential, commercial, institutional, and industrial installations. It features an annealed copper conductor with thermoplastic insulation engineered for high-temperature and moisture-resistant performance.
The THWN-2 designation provides a 90°C maximum conductor temperature rating in both wet and dry locations, making CU THWN-2 suitable for electrical systems where elevated operating temperatures and moisture exposure may occur.
CU THWN-2 is available in solid and stranded constructions depending on conductor size and installation requirements. Its smooth insulated surface provides good handling characteristics and facilitates installation through conduit, raceway, and other approved wiring systems.
CU THWN-2 is commonly used for:
Building power distribution
Commercial electrical wiring
Residential branch circuits
Industrial electrical installations
Feeder circuits
Branch circuits
Lighting circuits
Panelboards and distribution boards
Switchboards
Motor circuits
Control circuits
Electrical equipment wiring
Conduit and raceway systems
Cable trays where permitted
Wet and dry locations
Outdoor electrical systems where permitted
General-purpose electrical installations
Typical reference standards include:
UL 83 — Thermoplastic-Insulated Wires and Cables
ASTM B3 — Soft or Annealed Copper Wire
ASTM B8 — Concentric-Lay-Stranded Copper Conductors
NFPA 70 / NEC — National Electrical Code, where applicable
Final certification, markings, conductor construction, and permitted installation methods depend on the specific product construction and target market.
Material: Soft-drawn / annealed copper
Conductivity: High-conductivity copper
Construction: Solid or stranded
Conductor configuration selected according to conductor size and application
Material: Thermoplastic insulation
Color: Black, white, red, blue, green, yellow, or other colors upon request
Heat-resistant construction
Moisture-resistant construction
Designed for 90°C operation in wet and dry locations
Nominal insulation thickness according to applicable standards
Typical surface markings may include:
Manufacturer identification
Product designation
Conductor size
Voltage rating
Temperature rating
Applicable certification marks
Sequential footage or length marking where required
| Parameter | Specification |
|---|---|
| Product Type | THWN-2 Building Wire |
| Voltage Rating | 600 V |
| Conductor Material | Annealed Copper |
| Conductor Construction | Solid or Stranded |
| Insulation | Thermoplastic |
| Maximum Temperature — Dry | 90°C |
| Maximum Temperature — Wet | 90°C |
| Frequency | 50/60 Hz |
| Installation | Wet and dry locations as permitted |
| Conductor Class | Solid / Class B or equivalent stranded construction, depending on size |
| Applicable System | AC electrical distribution and equipment wiring |
| Size | Typical Construction |
|---|---|
| 14 AWG | Solid / Stranded |
| 12 AWG | Solid / Stranded |
| 10 AWG | Solid / Stranded |
| 8 AWG | Stranded |
| 6 AWG | Stranded |
| 4 AWG | Stranded |
| 3 AWG | Stranded |
| 2 AWG | Stranded |
| 1 AWG | Stranded |
| 1/0 AWG | Stranded |
| 2/0 AWG | Stranded |
| 3/0 AWG | Stranded |
| 4/0 AWG | Stranded |
| 250 kcmil | Stranded |
| 350 kcmil | Stranded |
| 500 kcmil | Stranded |
| 750 kcmil | Stranded |
| 1000 kcmil | Stranded |
Other conductor sizes, colors, insulation constructions, and packaging configurations are available according to project requirements.
| Characteristic | Typical Value / Description |
|---|---|
| Rated Voltage | 600 V |
| Conductor | Annealed Copper |
| Conductivity | High electrical conductivity |
| Insulation System | Thermoplastic |
| Maximum Operating Temperature | 90°C wet/dry |
| Frequency | 50/60 Hz |
| Conductor Construction | Solid or stranded |
| Electrical Application | Power, lighting, control and equipment wiring |
Conductor resistance is controlled according to the applicable conductor size and manufacturing standard.
CU THWN-2 is designed for electrical systems requiring enhanced thermal performance in both wet and dry locations.
90°C maximum conductor temperature in dry locations
90°C maximum conductor temperature in wet locations
Suitable for continuous operation within applicable ampacity limitations
Provides higher temperature capability than standard THWN construction
Supports applications where moisture exposure and elevated conductor temperatures may occur
Ampacity must be determined according to conductor size, installation method, ambient temperature, conductor grouping, and applicable electrical code requirements
Where connected equipment or terminals have a lower temperature rating, the lower applicable limitation shall govern.
CU THWN-2 is designed for applications where moisture exposure may occur while maintaining its 90°C wet-location temperature rating.
Typical applications include:
Wet-location conduit systems
Outdoor raceways where permitted
Underground raceways where permitted
Damp electrical equipment areas
Industrial facilities
Commercial buildings
Utility and infrastructure wiring systems
Electrical distribution systems
The actual installation method must comply with the product marking and applicable electrical code requirements.
CU THWN-2 provides:
Good flexibility for conduit installation
Reliable mechanical integrity
Smooth insulation surface
Resistance to normal installation abrasion
Stable dimensions under normal operating conditions
Good handling characteristics during pulling and termination
Stranded constructions are particularly suitable for larger conductor sizes and installations requiring improved flexibility.
Depending on the specific certification and construction, CU THWN-2 can be used in:
Wet locations
Dry locations
Damp environments
Indoor electrical systems
Outdoor installations where permitted
Conduit and raceway systems
Electrical enclosures
Distribution equipment
Industrial electrical infrastructure
The actual permitted installation method shall follow the product marking and applicable electrical code requirements.
CU THWN-2 may be installed in conduit, raceways, electrical enclosures, panelboards, switchboards, and other approved wiring systems.
Installation should comply with:
Applicable national and local electrical codes
NEC requirements where applicable
Conductor ampacity requirements
Raceway fill requirements
Minimum bending radius
Pulling tension limitations
Approved termination methods
Equipment terminal temperature ratings
For copper conductors, use connectors, lugs, terminals, and accessories approved for copper conductors and suitable for the conductor size.
600V voltage rating
90°C wet / 90°C dry temperature rating
Annealed copper conductor
Heat- and water-resistant thermoplastic insulation
Solid and stranded conductor options
Suitable for wet and dry locations within applicable ratings
High electrical conductivity
Good installation flexibility
Wide range of AWG and kcmil sizes
Suitable for commercial and industrial applications
Suitable for outdoor and moisture-exposed systems where permitted
Custom colors and packaging available
The 90°C rating in both wet and dry locations provides higher thermal capability than conventional THWN and THW constructions.
THWN-2 is specifically designed for wet-location applications while maintaining its 90°C conductor temperature rating.
Annealed copper conductors provide excellent electrical conductivity and reliable current-carrying performance.
Thermoplastic insulation provides dependable electrical isolation and mechanical protection during installation and normal operation.
CU THWN-2 is suitable for feeders, branch circuits, lighting, equipment wiring, control systems, panelboards, switchboards, and industrial power distribution.
Typical manufacturing quality controls include:
Conductor diameter inspection
Conductor resistance testing
Insulation thickness measurement
Insulation tensile and elongation testing
High-voltage withstand testing
Spark testing
Dimensional inspection
Surface marking verification
Finished-product appearance inspection
Finished-product electrical testing
Testing procedures can be adapted to applicable UL, ASTM, NEC, customer, and project requirements.
Typical packaging options include:
Coil
Reel
Wooden drum
Plywood drum
Export-grade packaging
Customer-specified packaging
Packaging configuration can be customized according to conductor size, shipping method, container loading requirements, and project length.
Available customization options may include:
Conductor size
Conductor construction
Insulation color
Surface marking
Packaging length
Reel or drum configuration
Sequential footage marking
Customer-specific labeling
Private-label production
Project-specific technical requirements
Technical documentation can be supplied according to project requirements, including:
Product datasheets
Technical specifications
Construction drawings
Conductor resistance data
Ampacity reference data
Material information
Test reports
Certificates and compliance documentation where applicable
Custom technical schedules for tenders and project submissions
CU THWN-2 is a 600V copper building wire with thermoplastic insulation designed for heat and moisture resistance, typically rated 90°C in both wet and dry locations.
The standard product is rated at 600 volts.
CU THWN-2 is typically rated:
90°C in dry locations
90°C in wet locations
Yes. THWN-2 is specifically designed for wet-location applications at its applicable 90°C wet rating, subject to product marking and installation requirements.
THWN is typically rated 75°C wet/dry, while THWN-2 is typically rated 90°C wet/dry.
Both are commonly rated 90°C wet/dry. THWN-2 specifically identifies the construction as heat- and water-resistant, while THW-2 identifies the 90°C wet/dry thermoplastic construction without the additional N designation.
THHN is generally a 90°C dry-rated thermoplastic wire and commonly uses a nylon coating. THWN-2 is specifically rated 90°C in both wet and dry locations. A product may carry both THHN and THWN-2 markings when it meets the corresponding construction and certification requirements.
Yes. It is commonly installed in conduit, raceways, electrical enclosures, panelboards, switchboards, and other approved wiring systems.
Yes. Stranded construction is commonly supplied for medium and large conductor sizes to improve handling and installation flexibility.
Yes. Conductor size, construction, insulation color, surface marking, packaging, reel length, labeling, and project-specific documentation can be customized subject to applicable standards.
SEO Product Title:
CU THWN-2 600V Copper Building Wire | 90°C Wet/Dry
Short Description:
CU THWN-2 is a 600V copper building wire featuring annealed copper conductors and heat- and water-resistant thermoplastic insulation with a 90°C wet/dry temperature rating.
Meta Description:
CU THWN-2 600V copper building wire features annealed copper conductors and thermoplastic insulation with a 90°C wet/dry rating for power distribution, building wiring, lighting, and industrial applications.
Suggested URL Slug:cu-thwn-2-600v-copper-building-wire
Product Image Title:
CU THWN-2 600V Copper Heat- and Water-Resistant Building Wire
Image Alt Text:
CU THWN-2 600V copper building wire with thermoplastic insulation for wet and dry electrical installations