CU XHH is a 600V copper building wire designed for electrical power distribution, commercial and industrial wiring, and equipment connections where high-temperature dry-location performance is required.
It features an annealed copper conductor with cross-linked polyethylene (XLPE) thermoset insulation. The XHH designation provides a 90°C maximum conductor temperature rating in dry locations, offering enhanced thermal capability compared with conventional 75°C thermoplastic building wires.
CU XHH is available in solid and stranded constructions depending on conductor size and application requirements. The thermoset insulation provides excellent electrical stability and resistance to thermal deformation under normal operating conditions.
CU XHH is commonly used for:
Building power distribution
Commercial electrical installations
Industrial electrical systems
Feeder circuits
Branch circuits
Panelboards and distribution boards
Switchboards
Motor circuits
Electrical equipment wiring
Control circuits
Conduit and raceway systems
Cable trays where permitted
Dry-location power distribution
General-purpose industrial wiring
Electrical infrastructure and equipment connections
Typical reference standards include:
UL 44 — Thermoset-Insulated Wires and Cables
ASTM B3 — Soft or Annealed Copper Wire
ASTM B8 — Concentric-Lay-Stranded Copper Conductors
NFPA 70 / NEC — National Electrical Code, where applicable
Final certification, markings, conductor construction, and permitted installation methods depend on the specific product construction and target market.
Material: Soft-drawn / annealed copper
Conductivity: High-conductivity copper
Construction: Solid or stranded
Conductor configuration selected according to conductor size and application
Material: Cross-Linked Polyethylene (XLPE) thermoset insulation
Color: Black, white, red, blue, green, yellow, or other colors upon request
High-temperature thermoset insulation
Designed for 90°C operation in dry locations
Excellent resistance to thermal deformation
Nominal insulation thickness according to applicable standards
Typical surface markings may include:
Manufacturer identification
Product designation
Conductor size
Voltage rating
Temperature rating
Applicable certification marks
Sequential footage or length marking where required
| Parameter | Specification |
|---|---|
| Product Type | XHH Building Wire |
| Voltage Rating | 600 V |
| Conductor Material | Annealed Copper |
| Conductor Construction | Solid or Stranded |
| Insulation | Cross-Linked Polyethylene (XLPE) |
| Insulation Type | Thermoset |
| Maximum Temperature — Dry | 90°C |
| Maximum Temperature — Wet | Not applicable unless additionally marked/certified |
| Frequency | 50/60 Hz |
| Primary Installation | Dry locations |
| Applicable System | AC electrical distribution and equipment wiring |
| Size | Typical Construction |
|---|---|
| 14 AWG | Solid / Stranded |
| 12 AWG | Solid / Stranded |
| 10 AWG | Solid / Stranded |
| 8 AWG | Stranded |
| 6 AWG | Stranded |
| 4 AWG | Stranded |
| 3 AWG | Stranded |
| 2 AWG | Stranded |
| 1 AWG | Stranded |
| 1/0 AWG | Stranded |
| 2/0 AWG | Stranded |
| 3/0 AWG | Stranded |
| 4/0 AWG | Stranded |
| 250 kcmil | Stranded |
| 350 kcmil | Stranded |
| 500 kcmil | Stranded |
| 750 kcmil | Stranded |
| 1000 kcmil | Stranded |
Other conductor sizes, colors, insulation constructions, and packaging configurations are available according to project requirements.
| Characteristic | Typical Value / Description |
|---|---|
| Rated Voltage | 600 V |
| Conductor | Annealed Copper |
| Conductivity | High electrical conductivity |
| Insulation System | XLPE Thermoset |
| Maximum Operating Temperature | 90°C dry |
| Frequency | 50/60 Hz |
| Conductor Construction | Solid or stranded |
| Electrical Application | Power, lighting, control and equipment wiring |
Conductor resistance is controlled according to the applicable conductor size and manufacturing standard.
CU XHH is designed for electrical systems requiring enhanced thermal performance in dry locations.
90°C maximum conductor temperature in dry locations
Thermoset XLPE insulation provides good dimensional stability at elevated temperatures
Reduced tendency toward thermal deformation compared with conventional thermoplastic insulation
Suitable for continuous operation within applicable ampacity limitations
Ampacity must be determined according to conductor size, installation method, ambient temperature, conductor grouping, and applicable electrical code requirements
Where connected equipment or terminals have a lower temperature rating, the lower applicable limitation shall govern.
CU XHH provides:
Good mechanical integrity
Stable insulation dimensions
Good resistance to thermal deformation
Smooth insulation surface
Resistance to normal installation abrasion
Good handling characteristics during pulling and termination
Stranded constructions are particularly suitable for larger conductor sizes and installations requiring improved flexibility.
CU XHH is primarily intended for dry-location applications.
Typical applications include:
Indoor electrical systems
Dry conduit and raceway installations
Electrical equipment
Panelboards
Switchboards
Industrial control and power systems
Commercial electrical infrastructure
Cable trays where permitted for dry locations
For wet locations, a product specifically marked and certified for wet-location use, such as XHHW or XHHW-2, should be selected.
CU XHH may be installed in conduit, raceways, electrical enclosures, panelboards, switchboards, and other approved dry-location wiring systems.
Installation should comply with:
Applicable national and local electrical codes
NEC requirements where applicable
Conductor ampacity requirements
Raceway fill requirements
Minimum bending radius
Pulling tension limitations
Approved termination methods
Equipment terminal temperature ratings
For copper conductors, use connectors, lugs, terminals, and accessories approved for copper conductors and suitable for the conductor size.
600V voltage rating
90°C dry-location temperature rating
Annealed copper conductor
XLPE thermoset insulation
High electrical conductivity
Excellent thermal stability
Good resistance to thermal deformation
Solid and stranded conductor options
Suitable for dry-location power distribution
Wide range of AWG and kcmil sizes
Custom colors and packaging available
CU XHH provides a 90°C maximum conductor temperature rating in dry locations, supporting applications requiring enhanced thermal capability.
Cross-linked polyethylene provides excellent electrical insulation and maintains dimensional stability under elevated operating temperatures.
Annealed copper provides excellent conductivity and reliable current-carrying performance.
The thermoset insulation system offers good resistance to softening and deformation under elevated-temperature conditions.
CU XHH is suitable for industrial power distribution, commercial electrical systems, feeders, branch circuits, equipment wiring, and dry-location conduit systems.
Typical manufacturing quality controls include:
Conductor diameter inspection
Conductor resistance testing
Insulation thickness measurement
Insulation tensile and elongation testing
High-voltage withstand testing
Spark testing
Dimensional inspection
Surface marking verification
Finished-product appearance inspection
Finished-product electrical testing
Testing procedures can be adapted to applicable UL, ASTM, NEC, customer, and project requirements.
Typical packaging options include:
Coil
Reel
Wooden drum
Plywood drum
Export-grade packaging
Customer-specified packaging
Packaging configuration can be customized according to conductor size, shipping method, container loading requirements, and project length.
Available customization options may include:
Conductor size
Conductor construction
Insulation color
Surface marking
Packaging length
Reel or drum configuration
Sequential footage marking
Customer-specific labeling
Private-label production
Project-specific technical requirements
Technical documentation can be supplied according to project requirements, including:
Product datasheets
Technical specifications
Construction drawings
Conductor resistance data
Ampacity reference data
Material information
Test reports
Certificates and compliance documentation where applicable
Custom technical schedules for tenders and project submissions
CU XHH is a 600V copper building wire with XLPE thermoset insulation, typically rated 90°C in dry locations.
The standard product is rated at 600 volts.
CU XHH is typically rated:
90°C in dry locations
Wet-location use is not assumed unless the product is additionally marked and certified for wet locations.
Standard XHH construction is primarily intended for dry locations. For wet-location applications, XHHW or XHHW-2 should generally be selected when the required certification and marking are provided.
XHH is generally intended for 90°C dry-location operation, while XHHW adds wet-location capability, typically with a lower 75°C wet rating.
XHH is typically 90°C dry, while XHHW-2 is typically 90°C wet/dry.
XHH uses XLPE thermoset insulation, while THHN uses thermoplastic insulation and typically includes a nylon coating. XHH provides a thermoset insulation system with high-temperature performance in dry locations.
Yes. It is commonly used in approved dry-location conduit and raceway systems.
Yes. Stranded construction is commonly supplied for medium and large conductor sizes to improve handling and installation flexibility.
Yes. Conductor size, construction, insulation color, surface marking, packaging, reel length, labeling, and project-specific documentation can be customized subject to applicable standards.
SEO Product Title:
CU XHH 600V Copper XLPE Building Wire | 90°C Dry
Short Description:
CU XHH is a 600V copper building wire featuring annealed copper conductors and XLPE thermoset insulation with a 90°C dry-location temperature rating for commercial and industrial electrical systems.
Meta Description:
CU XHH 600V copper building wire features annealed copper conductors and XLPE thermoset insulation with a 90°C dry rating for power distribution, industrial wiring, equipment, and conduit applications.
Suggested URL Slug:cu-xhh-600v-copper-xlpe-building-wire
Product Image Title:
CU XHH 600V Copper XLPE Thermoset Building Wire
Image Alt Text:
CU XHH 600V copper building wire with XLPE thermoset insulation for dry-location electrical installations