| Brand Name: | Morn |
| Model Number: | AL SE-R with XHHW-2 Inners |
| MOQ: | 50000 USD |
| Price: | USD quoted per meter based on specific cable specifications |
| Delivery Time: | 15~35 days upon receipt of advance payment |
| Payment Terms: | L/C |
AL SE-R with XHHW-2 Inners is an aluminum service entrance cable designed for residential, commercial, and industrial electrical distribution systems.
The cable consists of multiple aluminum conductors individually insulated with XHHW-2 cross-linked polyethylene insulation and assembled under a durable overall jacket. The XHHW-2 insulated conductors provide excellent electrical, thermal, and moisture-resistant performance, while the overall SE-R construction provides mechanical protection and a practical solution for service entrance and feeder applications.
The cable is designed for 600 V electrical distribution systems and is available in a wide range of conductor sizes and configurations.
AL SE-R with XHHW-2 Inners is suitable for:
Service entrance applications
Residential electrical service
Commercial building feeders
Industrial power distribution
Main feeder circuits
Sub-feeder systems
Distribution panels
Metering and service equipment
Residential and commercial construction
Above-ground electrical distribution
Wet and dry locations where permitted
UL 44 — Thermoset-Insulated Wires and Cables
UL 854 — Service-Entrance Cables
ASTM B230 — Aluminum 1350-H19 Wire
ASTM B231 — Concentric-Lay-Stranded Aluminum 1350 Conductors
Applicable NEC requirements
Applicable local electrical codes
Voltage Rating: 600 V
XHHW-2 Conductor Temperature Rating: 90°C Wet / Dry
Material: Aluminum
Electrical grade aluminum
Stranded, concentric-lay construction
Compact or standard construction available
High conductivity
Lightweight compared with equivalent copper conductors
The aluminum conductors are individually insulated before being assembled into the overall cable.
Each insulated conductor uses XHHW-2 insulation.
Material: Cross-Linked Polyethylene (XLPE)
Temperature Rating: 90°C wet / 90°C dry
Excellent dielectric strength
Excellent moisture resistance
Good thermal stability
Good resistance to aging and environmental exposure
The insulated conductors are assembled together to form the service entrance cable configuration.
Depending on the required construction, the cable may include:
Two insulated phase conductors
Three insulated conductors
Grounding conductor
Neutral conductor
Additional components according to project requirements
A durable overall jacket is applied over the assembled conductors.
Typical jacket materials may include:
PVC
Other suitable thermoplastic compounds according to project requirements
The jacket provides additional protection against mechanical damage, moisture, abrasion, and environmental exposure.
| Configuration | Typical Construction |
|---|---|
| 2 Conductor + Ground | Two XHHW-2 insulated aluminum conductors + grounding conductor |
| 3 Conductor + Ground | Three XHHW-2 insulated aluminum conductors + grounding conductor |
| 3 Conductor + Neutral | Three insulated conductors + neutral |
| Custom Configuration | According to project requirements |
Final construction shall be determined according to conductor size, application, applicable standards, and customer specifications.
| Parameter | Specification |
|---|---|
| Product Type | Aluminum Service Entrance Cable |
| Cable Designation | SE-R with XHHW-2 Inners |
| Conductor Material | Aluminum |
| Conductor Construction | Stranded / Concentric-Lay |
| Inner Insulation | XHHW-2 / XLPE |
| Overall Jacket | Thermoplastic Jacket |
| Voltage Rating | 600 V |
| Conductor Temperature Rating | 90°C Wet / Dry |
| Installation Locations | Wet and Dry Locations |
| Application | Service Entrance / Feeder / Distribution |
| Conductor Sizes | AWG / kcmil |
| Grounding Conductor | Available |
| Jacket Color | Black / Other Colors Available |
| UV Resistance | Available according to construction |
| Custom Construction | Available |
| AWG / kcmil | Approx. Area (mm²) | Typical Application |
|---|---|---|
| 6 AWG | 13.3 | Small Service / Feeder |
| 4 AWG | 21.2 | Service / Feeder |
| 2 AWG | 33.6 | Service / Distribution |
| 1 AWG | 42.4 | Service / Feeder |
| 1/0 AWG | 53.5 | Main Feeder |
| 2/0 AWG | 67.4 | Main Feeder |
| 3/0 AWG | 85.0 | Main Feeder |
| 4/0 AWG | 107 | Main Feeder |
| 250 kcmil | 127 | Distribution |
| 350 kcmil | 177 | Distribution |
| 500 kcmil | 253 | Large Feeder |
| 600 kcmil | 304 | Large Feeder |
| 750 kcmil | 380 | Large Feeder |
| 1000 kcmil | 507 | Large Distribution |
Other sizes and constructions are available upon request.
The cable combines lightweight aluminum conductors with high-performance XHHW-2 insulation to provide a reliable solution for low-voltage power distribution.
Key characteristics include:
High electrical conductivity
Low conductor weight
Stable conductor resistance
Excellent insulation resistance
90°C wet and dry conductor rating
Good moisture resistance
Excellent thermal stability
Suitable for feeder and service applications
Actual ampacity shall be determined according to conductor size, installation method, ambient conditions, number of current-carrying conductors, and applicable electrical codes.
| Characteristic | Rating |
|---|---|
| Voltage Rating | 600 V |
| XHHW-2 Wet Location Rating | 90°C |
| XHHW-2 Dry Location Rating | 90°C |
| Maximum Conductor Operating Temperature | 90°C |
| Short-Circuit Performance | According to conductor size and applicable requirements |
The 90°C XHHW-2 insulation provides enhanced thermal performance for properly engineered electrical distribution systems.
AL SE-R with XHHW-2 Inners may be installed in applications permitted by applicable electrical codes, including:
Service entrance systems
Electrical feeders
Residential distribution
Commercial buildings
Industrial facilities
Distribution panels
Metering equipment
Above-ground electrical systems
Installation shall comply with the applicable NEC and local electrical requirements.
Appropriate connectors, lugs, terminals, and accessories rated for aluminum conductors should be used.
600 V rated
Aluminum conductors
XHHW-2 insulated inner conductors
90°C wet and dry temperature rating
Service entrance cable construction
Excellent moisture resistance
Good thermal stability
Lightweight compared with copper
Suitable for residential, commercial, and industrial applications
Wide range of conductor sizes
Multiple cable configurations available
Custom constructions available
XHHW-2 insulation provides excellent electrical and thermal performance while maintaining reliable operation in wet and dry locations.
Aluminum reduces overall cable weight and provides a cost-effective alternative to copper for service and feeder applications.
The overall jacket provides additional mechanical and environmental protection to the assembled insulated conductors.
The cable is designed for low-voltage service entrance, feeder, and distribution applications up to 600 V.
Different conductor combinations, grounding configurations, sizes, and jacket constructions can be supplied according to project requirements.
Typical production testing and inspection may include:
Conductor resistance testing
Conductor dimensional inspection
Stranding inspection
Insulation thickness inspection
Insulation resistance testing
High-voltage testing
Jacket thickness inspection
Jacket integrity testing
Overall cable dimensional inspection
Visual inspection
Marking verification
Test reports and certificates can be provided according to project requirements.
Available packaging options include:
Wooden drums
Plywood drums
Steel-wooden drums
Coils for suitable sizes
Custom packaging
Drum lengths can be customized according to conductor size, cable construction, shipping requirements, and customer specifications.
Available customization options include:
Conductor size
Number of conductors
Neutral conductor
Grounding conductor
Conductor stranding
Insulation color
Jacket material
Jacket color
Cable marking
Drum length
Packaging
Customer-specific construction
Project-specific technical requirements
Technical support is available for:
Cable size selection
Service entrance cable configuration
Feeder design
Conductor configuration
Ampacity reference
Technical specifications
Project-specific construction
Inspection documentation
Test certificates
Packaging and shipping requirements
AL SE-R with XHHW-2 Inners is an aluminum service entrance cable consisting of individually XHHW-2 insulated aluminum conductors assembled under an overall protective jacket.
SE-R refers to a service entrance cable construction intended for service entrance and feeder applications in accordance with applicable requirements.
XHHW-2 is a cross-linked polyethylene insulated conductor construction designed for electrical applications requiring excellent thermal and moisture resistance, with a 90°C temperature rating for wet and dry locations.
The standard voltage rating is 600 V.
The XHHW-2 inner conductors are rated 90°C in wet and dry locations, subject to applicable standards and installation requirements.
Aluminum conductors provide a lightweight and economical solution for service entrance and feeder systems, particularly for larger conductor sizes.
The suitability for outdoor installation depends on the specific cable construction, jacket, exposure conditions, and applicable electrical code. UV-resistant constructions can be supplied when required.
Typical applications include residential service entrances, commercial feeders, industrial distribution systems, service equipment, and building electrical distribution.
Yes. The number and size of insulated conductors, neutral conductors, grounding conductors, and other construction details can be customized.
Yes. Black is commonly supplied, while other jacket colors can be considered according to project requirements.
SEO Product Title:
AL SE-R with XHHW-2 Inners 600V Aluminum Service Entrance Cable
Short Description:
AL SE-R with XHHW-2 Inners is a 600V aluminum service entrance cable featuring XHHW-2 insulated conductors with 90°C wet and dry temperature ratings for residential, commercial, and industrial power distribution.
Meta Description:
AL SE-R with XHHW-2 Inners is a 600V aluminum service entrance cable with 90°C XHHW-2 insulation, designed for residential, commercial, industrial, and feeder applications.
Product Image Title:
AL SE-R with XHHW-2 Inners 600V Aluminum Service Entrance Cable
Image Alt Text:
AL SE-R 600V aluminum service entrance cable with XHHW-2 insulated inner conductors