| Brand Name: | Morn |
| Model Number: | AL Single Conductor USE-2 |
| MOQ: | 50000 USD |
| Price: | USD quoted per meter based on specific cable specifications |
| Delivery Time: | 15~35 days upon receipt of advance payment |
| Payment Terms: | L/C |
AL Single Conductor USE-2 is a single-conductor aluminum power cable designed for underground service entrance, distribution, feeder, and utility applications.
The cable features a stranded aluminum conductor with cross-linked polyethylene (XLPE) insulation. The USE-2 construction provides excellent electrical insulation, moisture resistance, thermal stability, and long-term durability in demanding underground environments.
With a typical 90°C temperature rating for wet and dry locations, AL Single Conductor USE-2 provides reliable performance for underground electrical distribution systems.
The single-conductor construction allows multiple conductors to be installed together as phases, neutral, and grounding conductors according to the electrical system design.
AL Single Conductor USE-2 is suitable for:
Underground service entrance systems
Underground electrical distribution
Residential underground distribution
Commercial power distribution
Industrial power distribution
Underground feeder circuits
Utility distribution systems
Transformer connections
Service equipment connections
Direct-burial applications where permitted
Underground conduit and duct systems
Infrastructure and utility projects
Renewable energy applications where the applicable rating is suitable
UL 44 — Thermoset-Insulated Wires and Cables
ASTM B230 — Aluminum 1350-H19 Wire
ASTM B231 — Concentric-Lay-Stranded Aluminum 1350 Conductors
Applicable NEC requirements
Applicable utility specifications
Applicable local electrical codes
Typical Voltage Rating: 600 V
USE-2 Temperature Rating: 90°C Wet / Dry
Final voltage rating, certification, and construction shall be confirmed according to the specific product design and applicable requirements.
Material: Electrical-grade aluminum
Conductor type: Stranded aluminum
Construction: Concentric-lay stranded
Compact or standard construction available
High electrical conductivity
Lightweight compared with equivalent copper conductors
The aluminum conductor provides efficient electrical transmission while reducing overall cable weight.
Material: Cross-Linked Polyethylene (XLPE)
Designation: USE-2
Temperature Rating: 90°C Wet / Dry
Excellent dielectric strength
Excellent moisture resistance
Good thermal stability
Good resistance to aging
Suitable for demanding underground environments
This product is supplied as a single insulated conductor.
Multiple single conductors may be installed together to form complete electrical circuits according to project requirements.
| Parameter | Specification |
|---|---|
| Product Type | Single Conductor Underground Service Entrance Cable |
| Cable Designation | USE-2 |
| Conductor Material | Aluminum |
| Conductor Construction | Stranded / Concentric-Lay |
| Insulation | Cross-Linked Polyethylene (XLPE) |
| Cable Configuration | Single Conductor |
| Typical Voltage Rating | 600 V |
| Temperature Rating | 90°C Wet / Dry |
| Installation | Underground / Direct Burial / Conduit |
| Installation Environment | Wet and Dry Locations |
| Conductor Sizes | AWG / kcmil |
| Insulation Color | Black / Other Colors Available |
| UV Resistance | Available according to construction |
| Custom Construction | Available |
| AWG / kcmil | Approx. Area (mm²) | Typical Application |
|---|---|---|
| 6 AWG | 13.3 | Service / Distribution |
| 4 AWG | 21.2 | Service / Feeder |
| 2 AWG | 33.6 | Underground Feeder |
| 1 AWG | 42.4 | Underground Distribution |
| 1/0 AWG | 53.5 | Service / Distribution |
| 2/0 AWG | 67.4 | Distribution |
| 3/0 AWG | 85.0 | Distribution |
| 4/0 AWG | 107 | Main Feeder |
| 250 kcmil | 127 | Utility Distribution |
| 350 kcmil | 177 | Utility Distribution |
| 500 kcmil | 253 | Large Feeder |
| 600 kcmil | 304 | Large Feeder |
| 750 kcmil | 380 | Large Distribution |
| 1000 kcmil | 507 | Large Distribution |
Other conductor sizes are available according to project requirements.
AL Single Conductor USE-2 combines a stranded aluminum conductor with XLPE insulation to provide reliable electrical performance for underground distribution systems.
Key characteristics include:
High electrical conductivity
Low conductor weight
Stable conductor resistance
Excellent insulation resistance
High dielectric strength
Excellent moisture resistance
Good thermal stability
Reliable continuous operating performance
Actual ampacity depends on conductor size, installation method, soil conditions, ambient temperature, conductor spacing, number of current-carrying conductors, and applicable electrical codes.
| Characteristic | Rating |
|---|---|
| Typical Voltage Rating | 600 V |
| Maximum Continuous Operating Temperature | 90°C |
| Wet Location Rating | 90°C |
| Dry Location Rating | 90°C |
| Short-Circuit Performance | According to conductor size and applicable requirements |
The 90°C USE-2 insulation provides excellent thermal performance for underground service and distribution applications.
AL Single Conductor USE-2 may be installed in applications permitted by applicable electrical codes, including:
Direct-burial underground systems
Underground conduit
Underground ducts
Residential distribution systems
Commercial feeders
Industrial distribution systems
Utility distribution systems
Transformer connections
Service entrance systems where permitted
Installation shall comply with applicable electrical codes, utility specifications, burial depth requirements, and local regulations.
For direct-burial applications, installation conditions should be evaluated with respect to:
Soil thermal characteristics
Burial depth
Moisture exposure
Mechanical protection
Conductor spacing
Heat dissipation
Separation from other utilities
Single-conductor construction
Aluminum conductor
XLPE insulation
USE-2 rated construction
90°C wet and dry temperature rating
Suitable for underground applications
Excellent moisture resistance
Excellent thermal stability
Lightweight construction
Suitable for direct burial where permitted
Suitable for conduit and duct systems
Wide range of conductor sizes
Custom constructions available
USE-2 construction is designed for underground service entrance applications and provides enhanced performance for demanding underground electrical installations.
Aluminum provides a lightweight and economical solution for underground service and distribution systems, particularly for larger conductor sizes.
Cross-linked polyethylene insulation provides excellent dielectric strength, moisture resistance, thermal stability, and long-term electrical performance.
The USE-2 insulation provides a 90°C operating temperature rating for wet and dry locations under applicable requirements.
Individual conductors can be combined as phases, neutral, or grounding conductors according to the electrical system design.
Typical production testing and inspection may include:
Conductor resistance test
Conductor dimensional inspection
Stranding inspection
Insulation thickness measurement
Insulation resistance test
High-voltage test
Spark test where applicable
Cable dimensional inspection
Surface marking inspection
Visual inspection
Test certificates and inspection reports can be provided according to customer and project requirements.
Available packaging options include:
Wooden drums
Plywood drums
Steel-wooden drums
Coils for suitable conductor sizes
Custom packaging
Drum length can be customized according to conductor size, shipping requirements, and customer specifications.
Available options include:
Conductor size
Conductor stranding
Compact or standard conductor
Insulation thickness
Insulation color
Surface marking
Drum length
Packaging
Customer-specific specifications
Utility-specific requirements
Technical support can include:
Conductor size selection
Underground cable selection
Ampacity reference
Direct-burial application guidance
Utility project specifications
Technical documentation
Factory inspection
Test certificates
Packaging and shipping consultation
AL Single Conductor USE-2 is a single-conductor aluminum underground service entrance cable with XLPE insulation, designed for underground service, feeder, and distribution applications.
USE-2 stands for Underground Service Entrance, with a cable construction designed to meet the applicable USE-2 requirements for underground service entrance applications.
The standard construction uses cross-linked polyethylene (XLPE) insulation.
The typical USE-2 temperature rating is 90°C for wet and dry locations, subject to the specific cable construction and applicable certification.
The product is commonly supplied for 600V applications. The exact voltage rating should be confirmed according to the specific product construction and certification.
Yes. USE-2 constructions are commonly used for underground and direct-burial applications where permitted by the applicable electrical code and product certification.
USE-2 is a related but more specifically defined construction with additional performance requirements compared with basic USE constructions. USE-2 is commonly selected when the project specification specifically calls for USE-2.
URD is commonly used as an industry term for underground residential distribution cable, while USE-2 is a specific cable designation associated with underground service entrance requirements. A product may be marketed for URD applications while carrying a USE-2 rating, depending on its construction and certification.
Aluminum provides lower weight and generally lower material cost compared with copper, making it suitable for larger underground distribution conductors.
Yes. Multiple single conductors can be installed together as phases, neutral, and grounding conductors according to the electrical system design and applicable electrical code.
SEO Product Title:
AL Single Conductor USE-2 600V Aluminum Underground Service Entrance Cable
Short Description:
AL Single Conductor USE-2 is a 600V aluminum underground service entrance cable with XLPE insulation and a 90°C wet and dry temperature rating for underground distribution, feeders, utility, and service applications.
Meta Description:
AL Single Conductor USE-2 600V aluminum cable with XLPE insulation and 90°C rating for underground service entrance, direct burial where permitted, utility distribution, and feeder applications.