| Brand Name: | Morn |
| Model Number: | AL TECK90 5000V (GSIA) |
| MOQ: | 50000 USD |
| Price: | USD quoted per meter based on specific cable specifications |
| Delivery Time: | 15~35 days upon receipt of advance payment |
| Payment Terms: | L/C |
AL TECK90 5000V (GSIA) is a high-voltage aluminum conductor armored power cable designed for industrial power distribution, mining, processing plants, utility infrastructure, and other demanding fixed installations requiring enhanced mechanical protection.
The cable combines a stranded aluminum conductor with a high-performance XLPE insulation system, metallic shielding, galvanized steel interlocked armor, and a durable outer jacket. The GSIA construction provides excellent mechanical protection and is particularly suitable for installations where high impact resistance, crush resistance, and rugged mechanical protection are required.
The galvanized steel interlocked armor provides a robust protective layer around the cable while maintaining the flexibility required for practical industrial installation.
Typical Voltage Rating: 5,000 V
Conductor: Aluminum
Armor: Galvanized Steel Interlocked Armor (GSIA)
Insulation: XLPE
Typical Maximum Conductor Operating Temperature: 90°C
AL TECK90 5000V (GSIA) is designed for:
Industrial power distribution systems
Mining and mineral processing facilities
Oil and gas processing facilities
Power generation plants
Industrial substations
Utility infrastructure
Large industrial feeders
Motor feeders
Transformer connections
Processing and manufacturing plants
Heavy industrial equipment
Cable tray installations
Raceway and conduit systems
Underground industrial installations where permitted
Outdoor fixed installations
Harsh mechanical environments
Infrastructure and utility projects
The cable can be manufactured to applicable Canadian and North American requirements according to the final construction and certification configuration.
Typical reference standards include:
CSA C22.2 No. 131 — Type TECK90 Cable
CSA C22.2 No. 38 — Thermoset-Insulated Wires and Cables
CSA C68.3 — Shielded Power Cables
ASTM B230 — Aluminum Wire
ASTM B231 — Aluminum Conductors, Concentric-Lay-Stranded
Applicable Canadian Electrical Code requirements
Applicable project specifications and utility requirements
Voltage Rating: 5,000 V
Temperature Rating: 90°C maximum conductor operating temperature, subject to applicable requirements and installation conditions.
Final construction, dimensions, certification, and electrical ratings shall be confirmed according to the applicable standard and project specification.
The cable uses stranded electrical-grade aluminum conductors manufactured for reliable power transmission.
Conductor construction may be supplied in concentric-lay stranded or compact stranded configurations depending on conductor size and project requirements.
A semiconductive conductor shield may be incorporated into the high-voltage cable insulation system to provide controlled electrical stress distribution.
Cross-linked polyethylene (XLPE) insulation provides high dielectric strength, excellent thermal stability, and reliable electrical performance.
Key properties include:
High dielectric strength
Excellent thermal stability
Low dielectric losses
Moisture resistance
Good electrical aging performance
Good resistance to industrial operating conditions
A semiconductive insulation shield is applied over the insulation to provide controlled electrical stress distribution and support reliable high-voltage cable performance.
The cable may incorporate metallic shielding components according to the required fault-current capacity, grounding arrangement, and project specification.
Copper or aluminum shielding options can be considered depending on the cable design.
The GSIA construction incorporates galvanized steel interlocked armor around the cable.
The steel armor provides:
Excellent mechanical protection
High impact resistance
High crush resistance
Abrasion protection
Strong structural protection
Good resistance to installation damage
Additional grounding/bonding capability where properly designed and installed
The galvanized steel surface provides improved corrosion resistance compared with untreated steel.
A durable outer jacket provides additional protection against:
Moisture
Abrasion
Sunlight
Chemicals
Environmental exposure
Mechanical damage
Jacket material and color can be customized according to project requirements.
| Parameter | Specification |
|---|---|
| Product Type | High-Voltage Armored Power Cable |
| Designation | TECK90 |
| Configuration | GSIA |
| Conductor Material | Aluminum |
| Conductor Type | Stranded / Concentric-Lay |
| Insulation | XLPE |
| Conductor Shield | Semiconductive Layer |
| Insulation Shield | Semiconductive Layer |
| Metallic Shield | Copper or Aluminum, as specified |
| Armor | Galvanized Steel Interlocked Armor |
| Outer Jacket | Thermoplastic Jacket |
| Voltage Rating | 5,000 V |
| Maximum Conductor Temperature | 90°C |
| Installation | Fixed Installation |
| Environment | Indoor / Outdoor |
| Wet Location | Suitable where permitted by applicable construction |
| Direct Burial | Available subject to approved construction |
| Cable Tray | Suitable where permitted |
| Armor Type | GSIA |
| Conductor Sizes | Customizable |
| Jacket Color | Black / Custom |
| UV Resistance | Available |
| Oil Resistance | Available depending on jacket construction |
| Flame Performance | According to specified jacket construction and applicable standard |
Typical aluminum conductor sizes may include:
| AWG / kcmil | Typical Application |
|---|---|
| 1/0 AWG | Industrial feeders |
| 2/0 AWG | Industrial distribution |
| 4/0 AWG | High-current feeders |
| 250 kcmil | Industrial power systems |
| 350 kcmil | Large feeders |
| 500 kcmil | High-capacity distribution |
| 750 kcmil | Large industrial systems |
| 1000 kcmil | High-current applications |
Other conductor sizes are available according to project requirements.
The stranded aluminum conductor provides an efficient and economical solution for high-current power transmission while reducing overall cable weight compared with equivalent copper constructions.
XLPE insulation provides stable dielectric performance and high thermal resistance for demanding industrial power applications.
The conductor shield, insulation shield, and metallic shielding system are designed to provide controlled electrical stress distribution and appropriate grounding performance.
The galvanized steel interlocked armor provides mechanical protection and may contribute to the cable grounding and bonding system when the complete installation is designed accordingly.
The TECK90 designation provides a 90°C maximum normal conductor operating temperature, subject to the applicable standard, cable construction, and installation conditions.
Typical thermal characteristics include:
Continuous conductor operating temperature: 90°C
Good thermal stability
Low moisture absorption
Stable XLPE insulation performance
Suitable for continuous industrial operation
Short-circuit performance determined by conductor and metallic shield design
Actual ampacity depends on:
Conductor size
Installation method
Ambient temperature
Number of loaded conductors
Cable spacing
Soil thermal conditions for underground installations
Applicable electrical code requirements
GSIA provides a highly robust armored construction for installations exposed to significant mechanical stress.
Typical mechanical advantages include:
High impact resistance
High crush resistance
Abrasion resistance
Protection against installation damage
Strong structural support
Good resistance to industrial vibration
Galvanized steel corrosion protection
Reliable protection in demanding environments
Compared with aluminum interlocked armor, galvanized steel armor generally provides greater mechanical strength and is preferred where maximum armor protection is a priority.
AL TECK90 5000V (GSIA) may be installed according to the applicable electrical code, manufacturer recommendations, and project specifications.
Typical installation methods include:
Cable tray
Raceway
Conduit
Industrial equipment connections
Indoor fixed installation
Outdoor fixed installation
Underground installation where specifically permitted
Industrial distribution systems
Mining and processing facilities
Installation should consider:
Minimum bending radius
Pulling tension
Sidewall pressure
Cable weight
Ambient temperature
Armor bonding
Shield grounding
Termination requirements
Short-circuit current requirements
All cable accessories, terminations, and joints should be properly rated for the 5,000 V cable system.
5,000 V high-voltage design
Aluminum stranded conductor
XLPE insulation
TECK90 construction
Galvanized steel interlocked armor
High mechanical protection
High impact and crush resistance
Enhanced structural protection
Suitable for demanding industrial environments
Excellent thermal performance
Suitable for industrial power distribution
Custom configurations available
The galvanized steel interlocked armor provides strong protection against impact, crushing, abrasion, and mechanical damage.
The XLPE insulation and shielding system provide reliable electrical performance for 5,000 V industrial power distribution.
The cable is designed for demanding environments such as mining, processing plants, power generation facilities, and heavy industrial installations.
GSIA provides a strong armored construction where higher mechanical protection is required compared with lighter aluminum-armored configurations.
Aluminum conductors reduce cable weight and material cost while providing an efficient solution for high-current power distribution.
Each cable can be subject to comprehensive production and inspection procedures, including:
Conductor dimensional inspection
Conductor resistance testing
Insulation thickness inspection
Insulation electrical testing
Shield continuity inspection
Metallic shield inspection
Armor dimensional inspection
Armor integrity inspection
Jacket thickness inspection
High-voltage testing
Finished cable dimensional inspection
Appearance inspection
Routine electrical tests
Additional type tests and project-specific inspection documentation can be provided according to customer requirements.
Typical packaging options include:
Heavy-duty wooden drums
Steel-wooden drums
Export-grade cable reels
Customized reel dimensions
Waterproof wrapping
Moisture-resistant protection
Customized shipping marks
Packaging can be optimized according to cable length, conductor size, transportation method, and destination.
Available customization options include:
Conductor size
Conductor construction
XLPE insulation thickness
Shield configuration
Metallic shield material
Armor configuration
Galvanized steel armor thickness
Outer jacket material
Jacket color
Grounding configuration
Cable length
Cable marking
Packaging
Project-specific technical requirements
Technical documentation can be supplied according to project requirements, including:
Technical datasheets
Product specifications
Construction drawings
Dimensional information
Cable weight and diameter data
Routine test reports
Type test documentation
Material certificates
Certificate of compliance
Project-specific technical submittals
GSIA stands for Galvanized Steel Interlocked Armor. It refers to a cable construction using galvanized steel interlocked armor to provide enhanced mechanical protection.
GSIA uses galvanized steel interlocked armor, while AIA uses aluminum interlocked armor. GSIA generally provides higher mechanical strength and impact resistance, while AIA offers lower weight and excellent corrosion resistance.
TECK90 is a Canadian cable designation generally associated with armored industrial power cables with a maximum normal conductor operating temperature of 90°C under applicable conditions.
Aluminum provides a lower-weight alternative to copper and can offer an economical solution for large industrial power distribution systems.
Yes. The robust steel-armored construction makes it suitable for many mining and mineral-processing power applications, subject to the required project specification and applicable certification.
Yes, provided that the selected cable construction, jacket, installation method, and environmental conditions comply with the applicable requirements.
Underground installation may be possible depending on the final construction, burial conditions, mechanical protection, drainage, and applicable electrical code. The approved installation method should be confirmed for each project.
The armor may form part of the grounding and bonding system when the complete cable construction and installation are specifically designed for this purpose. Proper bonding and termination are required.
Yes. Conductor size, shielding system, armor construction, jacket, cable length, marking, and other parameters can be customized according to project requirements.
SEO Product Title:
AL TECK90 5000V GSIA Aluminum Armored High Voltage Power Cable
Short Description:
AL TECK90 5000V (GSIA) is an aluminum conductor high-voltage power cable with XLPE insulation and galvanized steel interlocked armor, designed for demanding industrial, mining, utility, and power distribution applications.
Meta Description:
AL TECK90 5000V GSIA aluminum armored power cable with XLPE insulation and galvanized steel interlocked armor for industrial, mining, utility, and high-voltage applications.
Product Image Title:
AL TECK90 5000V GSIA Aluminum Armored Power Cable
Image Alt Text:
AL TECK90 5000V GSIA aluminum conductor XLPE insulated galvanized steel interlocked armored power cable