| Brand Name: | Morn |
| Model Number: | AL TW |
| MOQ: | 50000 USD |
| Price: | USD quoted per meter based on specific cable specifications |
| Delivery Time: | 15~35 days upon receipt of advance payment |
| Payment Terms: | L/C |
AL TW is a 600V aluminum single-conductor building wire designed for general-purpose electrical wiring, feeder, branch circuit, lighting, and power distribution applications.
The cable features an electrical-grade aluminum conductor insulated with durable thermoplastic insulation. TW construction is designed for a maximum conductor operating temperature of 60°C in wet and dry locations under its traditional TW designation.
AL TW provides a lightweight and economical conductor solution for residential, commercial, industrial, and utility wiring systems where the applicable electrical code permits its use.
Residential electrical wiring
Commercial building wiring
General-purpose power distribution
Feeder circuits where permitted
Branch circuits
Lighting circuits
Control and auxiliary circuits
Electrical panels
Distribution boards
Conduit and raceway systems
Indoor fixed wiring
Wet and dry locations where permitted
Utility and infrastructure installations
Typical reference standards include:
UL 83 — Thermoplastic-Insulated Wires and Cables
ASTM B230/B230M — Aluminum Wire, 1350-H19
ASTM B231/B231M — Concentric-Lay-Stranded Aluminum 1350 Conductors
NFPA 70 / NEC — National Electrical Code
Applicable local electrical codes and installation requirements
The exact certification, marking, conductor construction, and permitted applications depend on the finished product configuration and applicable market requirements.
Material: Electrical-grade aluminum
Typical alloy: Aluminum 1350 series
Construction: Solid or stranded
Stranding: Concentric-lay stranded for applicable larger sizes
Surface: Smooth and clean
Conductor design optimized for electrical conductivity and installation performance
Material: Thermoplastic insulation
Insulation type: TW
Rated voltage: 600V
Maximum operating temperature: 60°C
Location rating: Wet and dry locations, where permitted
Standard insulation colors may include:
Black
White
Red
Blue
Green
Brown
Orange
Gray
Other colors can be supplied according to customer requirements.
| Parameter | Specification |
|---|---|
| Product Type | Aluminum Building Wire |
| Designation | TW |
| Conductor Material | Aluminum |
| Typical Conductor Grade | Aluminum 1350 |
| Conductor Construction | Solid or stranded |
| Insulation | Thermoplastic |
| Rated Voltage | 600V |
| Maximum Operating Temperature | 60°C |
| Location Rating | Wet and Dry, where permitted |
| Installation | Conduit, Raceway and approved wiring systems |
| Typical Conductor Sizes | 14 AWG–1000 kcmil |
| Conductor Identification | Color-coded insulation |
| Flame Performance | According to applicable requirements |
| UV Resistance | Depending on construction |
| Packaging | Coils, reels or drums |
Typical available sizes include:
| AWG / kcmil | Typical Construction |
|---|---|
| 14 AWG | Solid / Stranded |
| 12 AWG | Solid / Stranded |
| 10 AWG | Solid / Stranded |
| 8 AWG | Stranded |
| 6 AWG | Stranded |
| 4 AWG | Stranded |
| 3 AWG | Stranded |
| 2 AWG | Stranded |
| 1 AWG | Stranded |
| 1/0 AWG | Stranded |
| 2/0 AWG | Stranded |
| 3/0 AWG | Stranded |
| 4/0 AWG | Stranded |
| 250 kcmil | Stranded |
| 350 kcmil | Stranded |
| 500 kcmil | Stranded |
| 750 kcmil | Stranded |
| 1000 kcmil | Stranded |
Availability depends on the applicable TW construction and certification requirements.
600V
The aluminum conductor provides reliable electrical conductivity while reducing conductor weight compared with equivalent copper constructions.
Allowable ampacity depends on:
Conductor size
Ambient temperature
Number of current-carrying conductors
Installation method
Raceway configuration
Terminal temperature rating
Applicable electrical code
Final allowable ampacity shall be determined according to the actual installation conditions.
| Installation Condition | Maximum Conductor Temperature |
|---|---|
| Dry Location | 60°C |
| Wet Location | 60°C |
The traditional TW designation is associated with a 60°C maximum conductor operating temperature. Where a higher temperature rating is required, THW, THHW, THW-2, THWN, or THWN-2 constructions may be more appropriate depending on the installation requirements.
AL TW is designed for fixed electrical installations and provides:
Lightweight construction
Good handling characteristics
Suitable flexibility for applicable conduit installations
Reliable insulation integrity
Good resistance to normal installation handling
Clear conductor identification
The cable should be protected against excessive pulling tension, crushing, sharp edges, and bending beyond the manufacturer's recommended limits.
AL TW may be installed in approved:
Conduits
Raceways
Electrical panels
Distribution equipment
Other wiring systems recognized by applicable electrical codes
Installation should comply with the National Electrical Code (NEC) and applicable local regulations.
Aluminum conductors must be terminated using connectors, terminals, and lugs specifically approved for aluminum conductors.
Proper conductor preparation, connector compatibility, and specified tightening torque are important for long-term electrical reliability.
600V rated
60°C wet and dry
Electrical-grade aluminum conductor
Thermoplastic TW insulation
Lightweight compared with equivalent copper conductors
Wide range of conductor sizes
Suitable for general-purpose fixed wiring where permitted
Available in multiple insulation colors
Suitable for approved conduit and raceway systems
Custom conductor configurations available
Aluminum provides significantly lower conductor density than copper, reducing overall cable weight and simplifying handling.
AL TW provides a cost-effective aluminum conductor solution for applications where its temperature rating and construction are permitted.
The single-conductor thermoplastic construction provides a straightforward solution for basic electrical wiring systems.
Multiple AWG and kcmil sizes can be supplied to accommodate different electrical requirements.
Color-coded insulation provides convenient circuit identification during installation and maintenance.
Typical quality-control procedures may include:
Conductor resistance testing
Conductor diameter inspection
Stranding inspection
Insulation thickness measurement
High-voltage testing
Spark testing
Insulation integrity testing
Dimensional inspection
Marking verification
Finished product visual inspection
Additional testing can be provided according to customer specifications and applicable certification requirements.
AL TW can typically be supplied in:
Coils
Plastic reels
Wooden reels
Wooden drums
Export-grade packaging
Packaging length, reel dimensions, labeling, and identification markings can be customized according to project and shipping requirements.
Available options may include:
Conductor size
Solid or stranded construction
Insulation color
Conductor marking
Printing requirements
Standard package length
Reel or drum configuration
Private-label marking
Project-specific technical specifications
AL TW is a 600V aluminum single-conductor building wire with thermoplastic insulation, designed for general-purpose electrical wiring where its construction and temperature rating are permitted.
TW identifies a traditional thermoplastic-insulated wire construction with a maximum conductor operating temperature of 60°C.
The standard voltage rating is 600V.
The TW designation historically includes wet-location capability, but its 60°C temperature rating and the specific product marking must be considered. The applicable code and certification should always be checked before installation.
The main distinction is the temperature designation. Traditional TW is rated at 60°C, while THW is typically rated 75°C. THW is therefore generally preferred where higher continuous operating temperature capability is required.
Both are thermoplastic-insulated wire constructions, but THWN specifically identifies a wet-location construction and is typically rated 75°C wet/dry, while traditional TW is associated with a 60°C rating.
AL TW is traditionally rated 60°C, while AL THWN-2 is rated 90°C in wet and dry locations and provides substantially greater thermal capability.
Aluminum conductors can be used in feeder and distribution systems when the conductor size, ampacity, termination equipment, and installation method comply with applicable electrical codes.
Yes, where the specific TW construction is permitted by the applicable electrical code and product listing.
Typical conductor sizes can range from 14 AWG to 1000 kcmil, subject to the specific product construction and certification.
Yes. Standard and custom insulation colors can be supplied according to project requirements.
TW is a relatively lower-temperature designation. Where the installation requires 75°C or 90°C operation, a suitable THW, THHW, THW-2, THWN, or THWN-2 construction should be selected according to the applicable code and product listing.
SEO Product Title:
AL TW 600V Aluminum Building Wire | 60°C Thermoplastic Wire
Short Description:
AL TW is a 600V aluminum thermoplastic building wire designed for general-purpose electrical wiring and power distribution applications where its 60°C temperature rating is permitted.
Meta Description:
600V AL TW aluminum building wire with thermoplastic insulation and a traditional 60°C temperature rating. Available in AWG and kcmil sizes for approved electrical wiring applications.
Product Image Title:
AL TW 600V Aluminum Building Wire
Image Alt Text:
AL TW 600V aluminum thermoplastic insulated building wire
Suggested URL Slug: