Created with Pixso. NMD90 Cable 300V, Copper and Aluminum Non-Metallic Sheathed Building Wire for Residential Electrical Wiring
Detail Information
Place of Origin:
Thailand
Certification:
cUL / CSA
Cable Type:
UL Cables
Conductor Material::
CU / AL
Insulation Material::
PVC With Nylon Sheath
Jacket Material:
Flame-Retardant, Moisture-Resistant PVC
Rated Voltage:
300V
Rated Temperature:
-25°C To +90°C
Packaging Details:
Supplied on 75 m or 150 m spools, securely wrapped with protective film. Palletized packaging is available upon request for convenient handling and export transportation.
Supply Ability:
15,000 KM per year
Product Description

NMD90 CABLE 300V

Copper & Aluminum Non-Metallic Sheathed Building Cable

PRODUCT DESCRIPTION

NMD90 Cable is a 300V non-metallic sheathed building cable designed for residential electrical wiring and general-purpose building installations. It is available in copper and aluminum conductor configurations, depending on the required cable design.

The cable typically consists of solid or stranded conductors, PVC insulation with a nylon protective layer, and a durable PVC outer sheath. Its non-metallic construction provides electrical insulation, mechanical protection, and convenient installation for indoor building wiring applications.

NMD90 cable is commonly used in residential branch circuits, lighting systems, receptacle wiring, and other electrical distribution applications where permitted by applicable electrical codes.

APPLICATIONS

  • Residential building wiring

  • Indoor electrical installations

  • Lighting circuits

  • Receptacle and outlet circuits

  • Branch circuit wiring

  • Residential power distribution

  • General-purpose building electrical systems

  • New construction and renovation projects

STANDARDS

Typical applicable standards and requirements may include:

  • CSA C22.2 No. 48 – Nonmetallic-Sheathed Cable

  • Canadian Electrical Code (CEC)

  • Applicable ASTM conductor requirements, where specified

  • Customer-specific technical requirements

Final standards compliance and certification shall be confirmed according to the actual cable construction and approved product certification.

RATED VOLTAGE

300V

CONDUCTOR

Available conductor materials:

  • Copper

  • Aluminum, subject to the applicable cable design

Typical conductor characteristics:

  • Solid or stranded construction, depending on conductor size

  • Electrical-grade conductor material

  • Consistent conductor dimensions

  • Reliable electrical conductivity

  • Conductor sizes available according to product specifications

INSULATION

PVC Insulation with Nylon Protective Layer

The insulated conductors typically feature PVC insulation with a nylon protective layer.

Key characteristics include:

  • Reliable electrical insulation

  • Good dielectric properties

  • Abrasion resistance

  • Protection against normal installation stresses

  • Suitable thermal performance for the specified cable rating

  • Consistent insulation thickness and dimensional stability

JACKET

PVC Outer Sheath

The cable is protected by a durable PVC outer sheath designed for indoor building wiring applications.

Typical characteristics include:

  • Good mechanical protection

  • Abrasion resistance

  • Flame-retardant properties, subject to the applicable formulation and testing

  • Resistance to normal installation conditions

  • Available in different colors according to customer requirements

TYPICAL CONSTRUCTION

Component Description
Conductor Copper or Aluminum
Conductor Type Solid / Stranded
Primary Insulation PVC
Insulation Protective Layer Nylon
Grounding Conductor Bare Copper, where applicable
Overall Sheath PVC
Rated Voltage 300V
Maximum Conductor Temperature 90°C, subject to applicable construction

Actual conductor arrangements and material combinations depend on the selected product design.

TECHNICAL DATA

Parameter Specification
Product Type NMD90 Non-Metallic Sheathed Cable
Rated Voltage 300V
Conductor Material Copper / Aluminum, as specified
Conductor Construction Solid / Stranded
Insulation Material PVC
Insulation Protective Layer Nylon
Outer Jacket Material PVC
Grounding Conductor Bare Copper, where applicable
Temperature Rating 90°C, subject to applicable construction
Cable Configuration 2-Conductor / 3-Conductor with Ground, as specified
Application Residential Building Wiring
Installation Indoor, in accordance with applicable requirements

STANDARD CONFIGURATIONS

Configuration Typical Application
2 Conductors + Ground Residential Branch Circuits
3 Conductors + Ground Multi-Circuit and Specialized Wiring
Solid Conductor General Building Wiring
Stranded Conductor Applications requiring greater conductor flexibility

Available configurations depend on conductor size and the approved cable design.

COMMON SIZE RANGE

Conductor Size Typical Application
14 AWG Lighting and Branch Circuits
12 AWG Residential Receptacle Circuits
10 AWG Higher-Load Branch Circuits
8 AWG Selected Residential Electrical Applications
6 AWG Higher-Current Electrical Circuits
4 AWG Larger Residential Electrical Circuits
2 AWG Selected Feeder Applications

Available conductor sizes, materials, and configurations shall be confirmed according to the applicable NMD90 product requirements.

ELECTRICAL CHARACTERISTICS

NMD90 Cable is designed to provide reliable electrical insulation and stable performance in residential building wiring systems.

The conductor provides the required electrical conductivity for the specified circuit application, while the PVC insulation and nylon protective layer help maintain insulation integrity during normal installation and operation.

The overall PVC sheath provides additional mechanical protection for the insulated conductors.

Electrical resistance, ampacity, insulation thickness, and other performance parameters shall comply with the applicable product standard and approved cable design.

INSTALLATION

NMD90 Cable is intended for suitable indoor building wiring applications in accordance with the Canadian Electrical Code, applicable local regulations, and product certification requirements.

Typical applications include:

  • Residential wall and ceiling wiring

  • Indoor branch circuit installations

  • Lighting and receptacle circuits

  • Electrical distribution connections

  • Residential renovation projects

Installation requirements, including conductor sizing, ampacity, bending radius, support spacing, and termination methods, shall comply with applicable electrical codes and product specifications.

NMD90 cable should not be assumed suitable for direct burial, prolonged exposure to sunlight, or wet-location installations unless the specific product is approved for such applications.

KEY FEATURES

  • 300V rated cable construction

  • Copper and aluminum conductor options, subject to design

  • Solid and stranded conductor configurations

  • PVC insulation with nylon protective layer

  • Durable PVC outer sheath

  • 90°C temperature rating for applicable constructions

  • Suitable for residential building wiring

  • Multiple conductor configurations

  • Consistent insulation and sheath dimensions

  • Customizable cable length and packaging

QUALITY & PERFORMANCE

Manufacturing quality is controlled throughout conductor processing, insulation extrusion, nylon application, outer sheath extrusion, and finished-cable inspection.

Typical quality-control procedures may include:

  • Conductor resistance testing

  • Conductor dimensional inspection

  • Insulation thickness inspection

  • Nylon layer inspection

  • Outer sheath thickness inspection

  • High-voltage testing

  • Spark testing, where applicable

  • Finished-cable dimensional inspection

  • Visual inspection and marking verification

All testing and inspection requirements shall follow the applicable product standards and approved quality-control procedures.

PACKAGING

Available packaging options include:

  • Wooden reels

  • Plywood reels

  • Plastic reels

  • Coils

  • Export-grade cable drums

Cable length, reel dimensions, labeling, and packaging can be customized according to customer requirements.

CUSTOMIZATION

Available customization options may include:

  • Copper or aluminum conductor

  • Conductor size

  • Solid or stranded conductor

  • Number of conductors

  • Grounding conductor configuration

  • PVC insulation color

  • Nylon protective layer

  • PVC outer sheath color

  • Cable length

  • Cable marking

  • Reel dimensions

  • Packaging requirements

All customization options are subject to the applicable product design and certification requirements.

PRODUCT IDENTIFICATION

Typical product marking may include:

NMD90 300V CU/AL PVC NYLON

Additional marking information may include:

  • Manufacturer identification

  • Conductor material

  • Conductor size

  • Voltage rating

  • Temperature rating

  • Applicable certification markings

  • Production information

Final cable marking shall comply with the applicable product certification and customer requirements.

ADVANTAGES

NMD90 Cable offers several advantages for residential electrical wiring:

  • Non-metallic construction

  • Convenient handling and installation

  • PVC insulation and protective nylon layer

  • Additional protection from the PVC outer sheath

  • Multiple conductor configurations

  • Copper and aluminum options, where applicable

  • Suitable for residential wiring applications

  • Flexible packaging and customization options

PRODUCT SUMMARY

NMD90 Cable 300V is a non-metallic sheathed building cable designed for residential electrical wiring applications. Featuring copper or aluminum conductors, PVC insulation with a nylon protective layer, and a durable PVC outer sheath, it provides a practical solution for indoor building wiring, lighting circuits, receptacle circuits, and residential electrical distribution.

FREQUENTLY ASKED QUESTIONS

Q1. What is NMD90 Cable?

NMD90 Cable is a non-metallic sheathed electrical cable commonly used for residential building wiring in Canada and other applications where permitted by applicable electrical requirements.

Q2. What is the rated voltage of NMD90 Cable?

The cable is designed for a rated voltage of 300V, subject to the applicable product construction.

Q3. What conductor materials are available?

NMD90 cable can be specified with copper conductors. Aluminum conductor configurations should be confirmed according to the actual product design and applicable certification.

Q4. What insulation material is used?

The typical construction uses PVC insulation with a nylon protective layer.

Q5. What material is used for the outer sheath?

The overall outer sheath is made of PVC, providing mechanical protection for the cable.

Q6. What is the temperature rating?

The typical maximum conductor operating temperature is 90°C, subject to the specific cable construction and applicable certification.

Q7. Where is NMD90 Cable commonly used?

Typical applications include residential branch circuits, lighting circuits, receptacle wiring, and indoor building electrical installations.

Q8. Is NMD90 Cable suitable for outdoor installation?

NMD90 is generally intended for indoor building wiring. Outdoor suitability depends on the specific cable approval and applicable installation requirements.

Q9. Can NMD90 Cable be directly buried?

It should not be assumed suitable for direct burial. Always confirm the specific cable approval and local electrical code requirements before installation.

Q10. What conductor sizes are available?

Common building-wire sizes may include 14 AWG, 12 AWG, 10 AWG, 8 AWG, 6 AWG, and larger sizes, subject to the applicable product design.

Q11. Can the cable configuration be customized?

Conductor size, number of conductors, grounding arrangement, insulation color, sheath color, cable length, and packaging may be customized according to product requirements.

Q12. What information is required for a quotation?

Please provide the conductor material, conductor size, number of conductors, grounding configuration, required cable length, applicable standard or certification, order quantity, and destination for an accurate quotation.